System Platform 2023 P01
System Platform Enterprise 2023 P01
La patch 01 include:
- Varie correzioni di bug
- Inclusi hot fix (tutti i prodotti)
- Aggiunto il supporto per la grafica SVG con InTouch HMI
Il supporto grafico SVG, descritto in Supporto per l’importazione di SVG come grafica industriale , si applica solo alla grafica utilizzata nelle applicazioni InTouch HMI. In questa versione della patch non è possibile utilizzare la grafica SVG in una OMI ViewApp.
Program Name | Version | Technology Matrix Data Link |
AVEVA Platform Common Services 7.0.1 | 7.0.22305.2 | N/A |
AVEVA Application Server 2023 P01 and AVEVA OMI | 23.0.001 | AVEVA Application Server 2023 P01 |
AVEVA Historian 2023 P01 | 23.0.001 | AVEVA Historian 2023 P01 |
AVEVA Historian Client 2023 P01 | 23.0.001 | AVEVA Historian Client 2023 P01 |
AVEVA InTouch HMI 2023 P01 | 23.0.001 | AVEVA InTouch HMI 2023 P01 |
Operations Control Logger | 22.1.001 | N/A |
Questa patch può essere applicata solo a System Platform 2023.
Importante! System Platform non supporta ambienti misti di gruppo di lavoro/dominio di Windows. Come indicato nella Guida all’installazione di System Platform 2023, sebbene i gruppi di lavoro siano supportati, si consiglia la rete basata su dominio. Tuttavia, non è possibile utilizzare i nodi del gruppo di lavoro all’interno di un ambiente di dominio.
AVEVA Communication Drivers Pack 2023.1
Nuove funzionalità:
- Supporto di OI server/gateway OI come server PCS tramite plug-in PCS per la comunicazione IData v4 (interoperabilità tra portafogli)
- Supporta il nuovo Communication Drivers SDK per la creazione di driver di comunicazione OI Server con il framework AVEVA da parte degli utenti.
- Piattaforma di supporto Common Services (PCS) Framework 7.0.1 e SDK v3.0.1 Supporto di rete IPv6 per connettività client/server e origine dati.
- Supporta Microsoft .NET v6.0.14 Full Runtime e versioni successive.
- Supporta OpenSSL versione 1.1.1t
La versione 2023.1 include:
- OI-ABCIP 2023.1
- OI-ABTCP 2023.1
- OI-BACLITE 2023.1
- OI-CODESYS 2023.1
- OI-MBTCP 2023.1
- OI-MQTT 2023.1
- Gateway OI 2023.1
- OI-GESRTP 2023.1
- OI-MELSEC 2023.1
- OI-OMRONFINS 2023.1
- OI-SIDIRECT 2023.1
- OI-SOMAC 2023.1
- OI-SNMP 2023.1
- OI-TI500 2023.1
- OI-TWINCAT 2023.1
- OI-WEBSVC 2023.1
- Il driver SIM per la simulazione dei dati
Il Communication Drivers Pack fornisce una serie di driver con il componente Core, in un pacchetto di installazione.
Release video: Communication Drivers Pack 2023.1
AVEVA™ Communication Drivers Pack Help
Application Server 2017 Update 2
Dal 17 Maggio 2023 la versione di Application Server 2017 Update 2 entrerà nella fase di Mature Product Support, la terza e ultima fase del ciclo di vita del Product Support che continua fino al ritiro del prodotto.
Mature Product Support
Anno 5+
Assistenza tecnica attraverso i programmi esistenti
- Fornisce assistenza e diagnostica dei problemi di base utilizzando la knowledge base. In questa fase non sono previste ricerche approfondite sulla richiesta
- Bassa priorità di aggiornamento
- Si consiglia di eseguire l’aggiornamento a una versione corrente in cui i problemi originali sono stati già risolti


Novità
Aggiornamenti
Guida Rapida ai driver di comunicazione AVEVA – GuidaRapidaOIServer
Sistemi Operativi supportati nelle varie versioni di System Platform
SO Compatibility Matrix
Database supportati nelle varie versioni di System Platform
SQL Compatibility Matrix

Download
General
FAQ6266 : How To: Find out which version of .NET Framework is installed
FAQ1540 : Cannot install the common components, missing system files
Application Server
000033298 : The latest versions Win911 ( 2021 R2/R3 ) and Rockwell Studio 5000 ( 33.xx / 34.xx ) breaks System Platform
FAQ6080 : How To: Assign values to array elements – Application Server Input/Output Attributes for arrays
FAQ4651: Unable to install any component from System Platform 2012 if Historian Client is already installed on the machine
FAQ4139 : Error: ‘More than one session of the IDE is running.’ when attempting to configure security
FAQ4104 : AppServer 2.0 : SQLDataObject() and Error ‘Failed Writing to Assigned Attributes’
Recipe Management
000035457 : How Does the Recipe Management Standard license work? Can configure RMP Recipe regardless the use of the recipe management standard license?
Historian
000034352 : AVEVA Historian – Replication to PI – Adapter Buffer Size
FAQ14169 : How to retrieve data from old history blocks using new Historian runtime database?
FAQ5920 : How To: Change the password of the ‘sa’ user of the SQL Server or MSDE database
Intouch
FAQ7590 : Is it possible to build a query to select a certain group of alarms when using the Alarm Hot BackUp Manager?
FAQ6001 : How To: Automatic startup of Alarm Printer utility with a specified configuration.
FAQ5956 : How To: Add a user using the WWDosCommand(Net User) function. Is there a way to assign the user to a group?
FAQ5222 : The InTouch application is getting corrupted in a NAD Enviroment
FAQ7472 : How much historical data can be converted to a CSV file?
FAQ5582 : How To: Calculate exponential values, i.e. x to the power of n.
FAQ7099 : What are the maximum number of inbound connections to a computer?
FAQ4367 : Error: License file could not be found in which is required to run this program
FAQ4270 : Error: ‘Cannot load wwinsql.dll please install sql server client components’ on attempt to create an InSQL History Provider
FAQ4129 : Error: 1706, No valid source could be found for product Wonderware
FAQ1796 : Unable to communicate to remote View node using the InTouchProxy object; SLSPing does not see View running
FAQ1897 : WindowMaker or WindowViewer not showing (No GUI) but shows in the process list.
FAQ5608 : How To: Logon with SendKeys script when using InTouch security
FAQ5501 : How To: Rebuild a corrupted application
FAQ6252 : How To: Reduce the size of historical log files (.lgh and .idx)
FAQ6199 : How To: Detect if a SQL Server is available
FAQ5903 : How To: Close WindowViewer (view.exe) using a script function
FAQ5925 : How To: Use HistData utility
FAQ4718 : Alarm Client Control not working for time descending order
FAQ6281 : How To: Sort the newest alarms to the top of the AlarmDBView ActiveX Control.
InTouch OMI
000032897 : Troubleshooting Historian Client Web and OData Queries
InTouch Access Anywhere
FAQ13282 : Mixing Read-Only & None Read-Only Licenses in InTouch Access Anywhere 11.0 Patch01 (allegato)
AVEVA Edge
000034937 : AVEVA Edge as an OPC client cannot process OPC items enclosed within curly brackets in the connected OPC server
000034864 : Project documents updated in AVEVA Edge Studio are not synchronized with thin client stations
000035328 : AVEVA Edge may lose access to the AVEVA Insight Store and Forward database folder causing a situation similar to a DDoS attack
000035369 : Can AVEVA Edge run over a Virtual Machine?
Batch Management
000034810 : Import Batch Management Models from Two Standalone Batch Management Server(s) hosting each of its own Batch Management Application to a Common System Platform Galaxy
OIServer
TN1429 : OI Server Version and Build Information (allegato)
AVEVA Reports for Operations
000035298 : Interactive web elements in AVEVA Report do not work

Microsoft Security Updates Reports allegato ultimo report –> ATTENZIONE ai nuovi Release Date 24/05/2023
https://softwaresupportsp.aveva.com/#/securitycentral