Product News – Maggio 2023

Tech News
14 Giugno 2023

Tutte le novità di questo mese




System Platform 2023 P01

System Platform Enterprise 2023 P01

La patch 01 include:

  • Varie correzioni di bug
  • Inclusi hot fix (tutti i prodotti)
  • Aggiunto il supporto per la grafica SVG con InTouch HMI

Il supporto grafico SVG, descritto in Supporto per l’importazione di SVG come grafica industriale , si applica solo alla grafica utilizzata nelle applicazioni InTouch HMI. In questa versione della patch non è possibile utilizzare la grafica SVG in una OMI ViewApp.


Program Name  VersionTechnology Matrix Data Link
AVEVA Platform Common Services 7.0.1  7.0.22305.2N/A
AVEVA Application Server 2023 P01 and AVEVA OMI  23.0.001AVEVA Application Server 2023 P01
AVEVA Historian 2023 P01  23.0.001AVEVA Historian 2023 P01
AVEVA Historian Client 2023 P01  23.0.001AVEVA Historian Client 2023 P01
AVEVA InTouch HMI 2023 P01  23.0.001AVEVA InTouch HMI 2023 P01
Operations Control Logger  22.1.001N/A

Questa patch può essere applicata solo a System Platform 2023.

Importante! System Platform non supporta ambienti misti di gruppo di lavoro/dominio di Windows. Come indicato nella Guida all’installazione di System Platform 2023, sebbene i gruppi di lavoro siano supportati, si consiglia la rete basata su dominio. Tuttavia, non è possibile utilizzare i nodi del gruppo di lavoro all’interno di un ambiente di dominio.




AVEVA Communication Drivers Pack 2023.1

Nuove funzionalità:

  • Supporto di OI server/gateway OI come server PCS tramite plug-in PCS per la comunicazione IData v4 (interoperabilità tra portafogli)
  • Supporta il nuovo Communication Drivers SDK per la creazione di driver di comunicazione OI Server con il framework AVEVA da parte degli utenti.
  • Piattaforma di supporto Common Services (PCS) Framework 7.0.1 e SDK v3.0.1 Supporto di rete IPv6 per connettività client/server e origine dati.
  • Supporta Microsoft .NET v6.0.14 Full Runtime e versioni successive.
  • Supporta OpenSSL versione 1.1.1t

La versione 2023.1 include:

Il Communication Drivers Pack fornisce una serie di driver con il componente Core, in un pacchetto di installazione.

Release video: Communication Drivers Pack 2023.1

AVEVA™ Communication Drivers Pack Help



Application Server 2017 Update 2

Dal 17 Maggio 2023 la versione di Application Server 2017 Update 2 entrerà nella fase di Mature Product Support, la terza e ultima fase del ciclo di vita del Product Support che continua fino al ritiro del prodotto.

Mature Product Support
Anno 5+

Assistenza tecnica attraverso i programmi esistenti

  • Fornisce assistenza e diagnostica dei problemi di base utilizzando la knowledge base. In questa fase non sono previste ricerche approfondite sulla richiesta
  • Bassa priorità di aggiornamento
  • Si consiglia di eseguire l’aggiornamento a una versione corrente in cui i problemi originali sono stati già risolti


















Novità

Versione di Application Server corrispondente alla versione CDI elencata nel file GalaxyInfo.txt di un .cab

Aggiornamenti

Guida Rapida ai driver di comunicazione AVEVAGuidaRapidaOIServer

Sistemi Operativi supportati nelle varie versioni di System Platform
SO Compatibility Matrix

Database supportati nelle varie versioni di System Platform
SQL Compatibility Matrix


System Platform

TN044 – Gestione di un database in SQLite (file db) con System Platform

TN045 – Rimuovere DLL custom importate nella Galaxy







Download

PLC Viewer OMI App vers.3

Enterprise Integration vers.3


General

FAQ6266 : How To: Find out which version of .NET Framework is installed

FAQ1540 : Cannot install the common components, missing system files


Application Server

000033298 : The latest versions Win911 ( 2021 R2/R3 ) and Rockwell Studio 5000 ( 33.xx / 34.xx ) breaks System Platform


FAQ6080 : How To: Assign values to array elements – Application Server Input/Output Attributes for arrays

FAQ4651: Unable to install any component from System Platform 2012 if Historian Client is already installed on the machine

FAQ4139 : Error: ‘More than one session of the IDE is running.’ when attempting to configure security

FAQ4104 : AppServer 2.0 : SQLDataObject() and Error ‘Failed Writing to Assigned Attributes’


Recipe Management

000035457 : How Does the Recipe Management Standard license work? Can configure RMP Recipe regardless the use of the recipe management standard license?


Historian

000034352 : AVEVA Historian – Replication to PI – Adapter Buffer Size


FAQ14169 : How to retrieve data from old history blocks using new Historian runtime database?

FAQ5920 : How To: Change the password of the ‘sa’ user of the SQL Server or MSDE database


Intouch

FAQ7590 : Is it possible to build a query to select a certain group of alarms when using the Alarm Hot BackUp Manager?

FAQ6001 : How To: Automatic startup of Alarm Printer utility with a specified configuration.

FAQ5956 : How To: Add a user using the WWDosCommand(Net User) function. Is there a way to assign the user to a group?

FAQ5222 : The InTouch application is getting corrupted in a NAD Enviroment

FAQ7472 : How much historical data can be converted to a CSV file?

FAQ5582 : How To: Calculate exponential values, i.e. x to the power of n.

FAQ7099 : What are the maximum number of inbound connections to a computer?

FAQ4367 : Error: License file could not be found in which is required to run this program

FAQ4270 : Error: ‘Cannot load wwinsql.dll please install sql server client components’ on attempt to create an InSQL History Provider

FAQ4129 : Error: 1706, No valid source could be found for product Wonderware

FAQ1796 : Unable to communicate to remote View node using the InTouchProxy object; SLSPing does not see View running

FAQ1897 : WindowMaker or WindowViewer not showing (No GUI) but shows in the process list.

FAQ5608 : How To: Logon with SendKeys script when using InTouch security

FAQ5501 : How To: Rebuild a corrupted application

FAQ6252 : How To: Reduce the size of historical log files (.lgh and .idx)

FAQ6199 : How To: Detect if a SQL Server is available

FAQ5903 : How To: Close WindowViewer (view.exe) using a script function

FAQ5925 : How To: Use HistData utility

FAQ4718 : Alarm Client Control not working for time descending order

FAQ6281 : How To: Sort the newest alarms to the top of the AlarmDBView ActiveX Control.


InTouch OMI

000032897 : Troubleshooting Historian Client Web and OData Queries 


InTouch Access Anywhere

FAQ13282 : Mixing Read-Only & None Read-Only Licenses in InTouch Access Anywhere 11.0 Patch01 (allegato)


AVEVA Edge

000034937 : AVEVA Edge as an OPC client cannot process OPC items enclosed within curly brackets in the connected OPC server

000034864 : Project documents updated in AVEVA Edge Studio are not synchronized with thin client stations

000035328 : AVEVA Edge may lose access to the AVEVA Insight Store and Forward database folder causing a situation similar to a DDoS attack

000035369 : Can AVEVA Edge run over a Virtual Machine?


Batch Management

000034810 : Import Batch Management Models from Two Standalone Batch Management Server(s) hosting each of its own Batch Management Application to a Common System Platform Galaxy


OIServer

TN1429 : OI Server Version and Build Information (allegato)


AVEVA Reports for Operations

000035298 : Interactive web elements in AVEVA Report do not work



Microsoft Security Updates Reports allegato ultimo report –> ATTENZIONE ai nuovi Release Date 24/05/2023